Xinxiang SIMO Blower Co., Ltd.

SIMO Blower Industrial Blower Fan Manufacture Experts First-class products,first-class technology, first-class service

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Boiler Fan /

250℃ Max Single Inlet Air Circulation CFB Boiler Fan

Contact Now
Xinxiang SIMO Blower Co., Ltd.
Visit Website
City:xinxiang
Province/State:henan
Country/Region:china
Contact Person:Kevin Sun
Contact Now

250℃ Max Single Inlet Air Circulation CFB Boiler Fan

Ask Latest Price
Video Channel
Brand Name :SIMO
Model Number :SIMO Blower
Certification :CE, ISO9001:2008,TUV
Place of Origin :Henan China
MOQ :1 Set
Price :Negotiable
Payment Terms :T/T, L/C, Payment Term Is Negotiable
Supply Ability :500 Sets Per Month
Delivery Time :15-35 Days
Packaging Details :Export Wooden Case Packing, Steel pallet Packing
Material :Carbon Steel/Alloy Steel/Stainless Steel
After-sales Service Provided :Field installation, commissioning and training
Power source :Three Phase AC Motor
Bearing cooling :Air cooling or Circulating Water cooling
Lubrication :Oil bath lubrication
Medium :Clean air/Dusty air
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

CFB Boiler Single Inlet Wear Resistant Air Circulation Fan

Introduction:

This series of fans can also be used for dust removal, mine ventilation and general ventilation systems. The blower delivers air, and the induced draft fan delivers flue gas or gas containing foreign particles.

The 5-06 series fan can be used in the feeding system of 2-670t/h steam boiler in thermal power plants, it can also meet the requirements of the high-pressure head performance parameters of the fluidized bed furnace.

It can be used for more than four years when the concentration of impurities is less than 200 mg/m3.

If it contains a lot of impurities, it also can be used, but it will shorten the service life.

The maximum operating temperature of the induced draft fan must not exceed 250°C.

The performance of the fan is expressed by parameters such as fan flow, full pressure, spindle speed, shaft power and efficiency.

Technical data:

Air Fan

series

Air Fan

model

Air Fan

Rotation Speed
(r/min)

Air Fan

Total Pressure
(Pa)

Air Fan

Air Capacity
(m3/h)

Air Fan

Power
(kW)

5-06

Air Fan

8D 1450 2592~1989 12028~20607 15
10D 1450 4051~3108 23493~40249 55
11D 1450 3036~2329 31269~53571 55
12.4D 1450 3858~2960 44792~76740 90

Advantages and Features:

1. Impeller:

12 pieces of backward aerofoil blades are welded between the Arc cone front plate and the flat shaped rear plate. Because of the use of airfoil blades, the fan is guaranteed to have high efficiency, low noise and high strength. The impeller is corrected by static and dynamic balance, so the operation is stable. Forced draught fan and induced draught fan of the same machine number have same impeller structure.

2. Casing:

The casing is a volute welded by ordinary steel plates.

The casing of a single suction fan is made in three different forms: The No. 8 to 12 casing is made into an integral structure and cannot be disassembled; The No. 14 to 16 casing is made into a two open structure; The No. 18~29.5 casing is made into a three open structure.

The induced draft fan and the volute plate are appropriately thickened to prevent wear.

3. Inlet:

The converging and streamlined air inlet is made into a unitary structure and bolted to the inlet side of the fan.

4. Adjustment door:

A device for regulating the flow of the fan, axially mounted in front of the air inlet. The adjustment range is from 0° (full open) to 90°(fully closed).

5. Transmission parts:

The main shaft of the transmission part is made of high-quality steel, and the 5-06 series of fans are all made of roller bearings.

The bearing housing is available in two forms: No. 8 ~ 16 uses a whole cylindrical bearing housing; No18 ~ 29.5 uses two independent pillow bearing boxes.

The bearing housing is equipped with a thermometer and an oil level indicator (only the induced draft fan). The lubricating oil uses 46# mechanical oil, and the oil quantity is implemented according to the oil level mark. When the No8-16 integral cylindrical bearing housing uses dry oil, the oil retaining plate should be added to the ball side of the bearing housing, and the fixing grooves communicate with each other. The induced draft fan is equipped with a water cooling device, so a water supply pipe must be installed. Water consumption varies with temperature, and is generally considered to be 0.5 to 1 m3/h.

FAQ

1,Q: What’s the MOQ of your company?

A: The MOQ is 1set.

2,Q: How long is the delivery time?

A : A:5-35 days.

3,Q : What’s your payment terms?

A : T/T, L/C, or Negotiable.

4,Q: What’s your warranty?
A: 1 year.
5,Q: Is your company factory or trade company?

A: We have our own factory, our type is factory +trade.

250℃ Max Single Inlet Air Circulation CFB Boiler Fan

250℃ Max Single Inlet Air Circulation CFB Boiler Fan

250℃ Max Single Inlet Air Circulation CFB Boiler Fan250℃ Max Single Inlet Air Circulation CFB Boiler Fan

Inquiry Cart 0