Xinxiang SIMO Blower Co., Ltd.

SIMO Blower Industrial Blower Fan Manufacture Experts First-class products,first-class technology, first-class service

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Boiler Fan /

Industrial Air Supply Boiler Fan Corrosion Resistant Backward Curved

Contact Now
Xinxiang SIMO Blower Co., Ltd.
Visit Website
City:xinxiang
Province/State:henan
Country/Region:china
Contact Person:Kevin Sun
Contact Now

Industrial Air Supply Boiler Fan Corrosion Resistant Backward Curved

Ask Latest Price
Video Channel
Brand Name :SIMO
Model Number :SIMO Blower 4-10
Certification :CE, ISO9001:2008,TUV
Place of Origin :Henan China
MOQ :1 Set
Price :Negotiable
Payment Terms :T/T, L/C, Payment Term Is Negotiable
Supply Ability :500 Sets Per Month
Delivery Time :15-35 Days
Packaging Details :Export Wooden Case Packing, Steel pallet Packing
Material :Carbon Steel/Alloy Steel/Stainless Steel
Motor :SIEMENS/ABB/By your demand
Bearing Type :Rolling bearing
Noise :Optional
Electric Current Type :AC
more
Contact Now

Add to Cart

Find Similar Videos
Electrical Motor Centrifugal Exhaust Fan Rotor Boiler Soot Blower 00:37
Electrical Motor Centrifugal Exhaust Fan Rotor Boiler Soot Blower
Industrial Boiler Fan High Efficiency less than 900000m³/H 00:46
Industrial Boiler Fan High Efficiency less than 900000m³/H
High Speed 0-3000rpm Boiler Fan With Pressure ≤20000Pa And Noise ≤85dB 01:01
High Speed 0-3000rpm Boiler Fan With Pressure ≤20000Pa And Noise ≤85dB
Coal Fired Primary Boiler Centrifugal Fan Induced Draft 00:34
Coal Fired Primary Boiler Centrifugal Fan Induced Draft
High Efficiency 440V 10KV SA FAN Boiler Air Volume ≤900000m3/H 00:34
High Efficiency 440V 10KV SA FAN Boiler Air Volume ≤900000m3/H
Industrial 4000rpm Boiler Induced Draft Fan Customizable 00:35
Industrial 4000rpm Boiler Induced Draft Fan Customizable
AC Motor Single Inlet Abrasion Resistant Industrial Kilns Boiler Fan 00:45
AC Motor Single Inlet Abrasion Resistant Industrial Kilns Boiler Fan
Fluidized Bed Boiler Blower Fan High Performance Large Air Flow 00:40
Fluidized Bed Boiler Blower Fan High Performance Large Air Flow
Industrial Boiler Fan With Air Or Water Cooling System For Heat Resistant Applications 00:34
Industrial Boiler Fan With Air Or Water Cooling System For Heat Resistant Applications
High Efficiency FD Fan For Boiler Less 900000m3/H 440V 10KV 00:20
High Efficiency FD Fan For Boiler Less 900000m3/H 440V 10KV
View Product Description

Industrial Air Supply Boiler Fan Corrosion Resistant Backward Curved

Introduction

G4-10 and Y4-10 series ventilation and induced draft fans are suitable for the ventilation and induced draft fan systems of 2~670T/h steam boilers in thermal power plants.

Motor is carefully matched to the fan load, protection level IP54, and insulation class F. Motor ball bearings are used and lubricated. Motor and drives are isolated from the air stream to avoid grease or dirt accumulation.

Detail introduction

Fan surface shall be polished and cleaned up to remove particulates, welding slag, burrs, sharp edge, iron, oil, then epoxy coating or high temperature coating for high temperature environments use, fan surface shall be free of sags, wrinkle, blisters, exposed metal or peeling after coating.

Technical data

series model Rotation Speed
(r/min)
Total Pressure
(Pa)
Air Capacity
(m³/h)
Power
(kW)
4-10 8D 1450 2104~1400 16156~30993 18.55
9D 960 ~ 1450 775 ~ 2668 15229 ~ 44128 11 ~ 37
10D 730 ~ 1450 553 ~ 3301 15886 ~ 60533 7.5 ~ 55
11D 730 ~ 1450 669 ~ 4003 21144 ~ 80570 11 ~ 90
12D 730 ~ 1450 797 ~ 4777 25661 ~ 104600 15 ~ 132
14D 730 ~ 1450 1086 ~ 6541 43591 ~166100 37 ~ 315
16D 580 ~ 960 895 ~ 3709 51699 ~ 164150 45 ~ 185
18D 580 ~ 960 1133 ~ 4710 73610 ~ 233730 75 ~ 280
20D 580 ~ 960 1400 ~ 5837 100970 ~ 320610 110 ~ 520
22D 480 ~ 960 1216 ~ 6865 116000 ~ 434000 140 ~ 850
25D 480 ~ 730 1579 ~ 5138 171000 ~ 484000 165 ~ 700
28D 375 ~ 730 1205 ~ 6400 187000 ~ 680000 320 ~ 1250
29.5D 596 ~ 745 3236 ~ 7218 348000 ~ 810000 800 ~ 1600

Product Features

The fan shall be single-inlet with steel backward curved centrifugal wheel. The drive type shall be direct drive, coupling drive and belt drive. Structure of the fan shall be undone easily for maintenance and cleaning.

FAQ


1,What parameters need to be provided when you design the industrial centrifugal fans?

A: Air flow, total pressure or static pressure, inlet temperature, local voltage and frequency, Altitude etc.
If there is flammable and explosive gas, or big dust loading in the medium, please also inform the designer.
2,How about your company’s pre-sales service and after-sales service?
A: Before our cooperation, we have the professional technical team to help you make the technical solution according to your working condition, to make sure the centrifugal fan efficiency operation.
After sales service, we will offer 12 months’ repairing service, and provide lifelong follow-up services. Besides, our engineers are available for going abroad to offer the repairing service.
3,Does your company have qualifications?
A: SIMO Blower has obtained ISO 9001-2008, CE, TUV certifications and so on.

Industrial Air Supply Boiler Fan Corrosion Resistant Backward Curved

Industrial Air Supply Boiler Fan Corrosion Resistant Backward Curved

Industrial Air Supply Boiler Fan Corrosion Resistant Backward Curved

Inquiry Cart 0
You May Like
160kw Induced Draft Fan For Industrial Dust Collector Centrifugal
160kw Induced Draft Fan For Industrial Dust Collector Centrifugal
16mn Low Pressure Forward Corrosive Gas Delivery Boiler Fan
16mn Low Pressure Forward Corrosive Gas Delivery Boiler Fan
4-72 Single Inlet Centrifugal Fan For Boiler Suction AC Electric
4-72 Single Inlet Centrifugal Fan For Boiler Suction AC Electric
High Efficiency 440V 10KV SA FAN Boiler Air Volume ≤900000m3/H
High Efficiency 440V 10KV SA FAN Boiler Air Volume ≤900000m3/H
440V 10KV Boiler Fan With 100000 Hours Lifespan
440V 10KV Boiler Fan With 100000 Hours Lifespan
Stainless Steel Boiler Fans Less 20000Pa Pressure For Industrial
Stainless Steel Boiler Fans Less 20000Pa Pressure For Industrial
SA Fan Boiler 1-2000KW Q235 High Air Volume Less 900000m3/H
SA Fan Boiler 1-2000KW Q235 High Air Volume Less 900000m3/H
High Efficiency FD Fan For Boiler Less 900000m3/H 440V 10KV
High Efficiency FD Fan For Boiler Less 900000m3/H 440V 10KV
1 Year Warranty Boiler ID Fan For Pressure Less Than 20000Pa
1 Year Warranty Boiler ID Fan For Pressure Less Than 20000Pa
High Speed 0-3000rpm Boiler Fan With Pressure ≤20000Pa And Noise ≤85dB
High Speed 0-3000rpm Boiler Fan With Pressure ≤20000Pa And Noise ≤85dB
High Efficiency Steam Boiler Fans In Customer'S Request Size
High Efficiency Steam Boiler Fans In Customer'S Request Size
High Pressure Boiler Fan 50-5000kg For Industrial
High Pressure Boiler Fan 50-5000kg For Industrial
Industrial Boiler Fan High Efficiency less than 900000m³/H
Industrial Boiler Fan High Efficiency less than 900000m³/H
Boiler ID Fan Noise Less 85dB 100000h Lifespan For Application
Boiler ID Fan Noise Less 85dB 100000h Lifespan For Application
0-3000rpm SA Fan Boiler 10kv Boiler Exhaust Blower Centrifugal Fan
0-3000rpm SA Fan Boiler 10kv Boiler Exhaust Blower Centrifugal Fan
Send your message to this supplier
*From:
*To:

Xinxiang SIMO Blower Co., Ltd.

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now